A pharmaceutical production equipment specialist built around GMP

SHINWONGPharmaceutical Manufacturing
VALIDATION AND SERVICE

Validation and Service

From design qualification through IQ, OQ and PQ documents to installation, training, preventive maintenance and spare parts.

Qualification support

We do not stop at handover. We stay with the project until the customer can face an inspection with that machine.

StageNameContent
DQDesign qualificationConfirms the design specification meets the user requirement, with the risk assessment reflected
FATFactory acceptance testFunction and performance checked before shipment, witnessed by the customer
SATSite acceptance testRepeated on site after installation under real conditions
IQInstallation qualificationDrawings, certificates, utility connections and instrument calibration verified
OQOperational qualificationFunctions and alarms checked across the full operating range
PQPerformance qualificationPerformance confirmed with consecutive batches of the real product

Documents we hand over

  • User requirement specification and design specification
  • Mechanical drawings, piping diagrams, electrical and control drawings
  • Material certificates, weld records and surface finish records
  • Instrument calibration certificates and the calibration schedule
  • IQ, OQ and PQ protocols with the executed reports
  • Operation and maintenance manuals, parts list and the preventive maintenance plan
  • Software version record and a description of the audit trail
Quality passed stamp

Only equipment that has passed the factory acceptance test moves to packing.

Installation and training

Installation starts with the access route. Ceiling height, door widths, floor loading and utility positions are measured in advance so that nothing has to change on the day. After installation, operators and maintenance staff are trained separately.

  • Operator training: running recipes, daily checks, cleaning procedures, responding to alarms
  • Maintenance training: strip down and rebuild, consumable replacement, fault finding
  • Quality training: what to check in the records, reading electronic records and the audit trail
Assembly and commissioning
Instrument calibration and checking
Instrument calibration and checking

Maintenance and parts

Preventive maintenanceOne or two site visits a year with a written report
Breakdown responseDomestic response within working days; overseas, the partner responds first with head office support
Remote diagnosticsWith customer approval we connect remotely to review alarms and parameters
ConsumablesFilters, gaskets, punches and dies, belts, with recommended replacement intervals
Spare partsWe aim to supply key parts for at least ten years after delivery